California’s indoor heat standard has applied since July 2024. In a Kern County summer, it turns warehouse ventilation, cool-down space and lease language into compliance questions.
The Cal/OSHA indoor heat rule, Title 8 section 3396, was approved by the Occupational Safety and Health Standards Board on June 20, 2024 and took effect July 23, 2024. It covers indoor workplaces that reach 82 F. Employers must provide water, cool-down areas, measurements, a written plan and training, plus engineering controls at 87 F (or at 82 F with heat-restrictive clothing or radiant heat). It applies now to Kern County warehouses, plants and packing sheds.
Indoor heat rule at a glance
| Item | Detail |
|---|---|
| Regulation | Cal. Code Regs., tit. 8, section 3396, Heat Illness Prevention in Indoor Places of Employment |
| Adopted by | Occupational Safety and Health Standards Board, June 20, 2024 |
| Effective | July 23, 2024 |
| Enforced by | Cal/OSHA (Division of Occupational Safety and Health) |
| Trigger | Indoor temperature of 82 F or more while employees are present |
| Engineering controls | Required at 87 F temperature or heat index, or at 82 F with heat-restrictive clothing or high radiant heat |
| Who it affects | Warehouses, distribution centers, plants, food processing, packing sheds, vehicles without working air conditioning, shipping containers |
| Main exemptions | Brief exposures under 15 minutes per hour at 82 F to 95 F, telework sites, emergency operations, certain correctional facilities |
| Status | In force; Cal/OSHA circulated a revised discussion draft of its heat rules in August 2026; federal OSHA rule not final |
| Pending | Formal rulemaking on Cal/OSHA’s August 2026 draft; any federal OSHA final rule |
Key takeaways
- Title 8 section 3396 has applied to California indoor workplaces since July 23, 2024, whenever the indoor temperature reaches 82 F while employees are present.
- Employers must use engineering controls such as ventilation, fans, evaporative coolers or air conditioning when the temperature or heat index reaches 87 F. The trigger drops to 82 F where workers wear heat-restrictive clothing or work near high radiant heat.
- Cool-down areas must be kept below 82 F unless the employer shows that is infeasible. New employees must be closely observed for their first 14 days.
- Temperature and heat index records must be kept for 12 months or until the next measurements, whichever is later.
- Federal OSHA proposed a national heat standard on Aug. 30, 2024. As of April 2026, according to law firm Ogletree Deakins, the federal regulatory agenda listed no target date for a final rule.
What is the Cal/OSHA indoor heat rule?
It is California’s workplace safety standard for heat inside buildings and enclosed spaces. The Standards Board approved section 3396 on June 20, 2024, and it went into effect July 23, 2024. It sits alongside the long-standing outdoor heat rule, section 3395, which covers farm fields, yards and other outdoor work. Cal/OSHA’s heat illness prevention page collects guidance for both.
The indoor rule matters in Kern County because so much of the local economy works indoors: distribution centers, food and nut processing, packing sheds, manufacturing and maintenance shops. National brokerage data count 67.4 million square feet of industrial inventory in the Bakersfield market in a Q2 2026 industrial report. Much of the work in that space happens in Valley summer heat.
What does the Cal/OSHA indoor heat rule require?
The regulation layers duties by temperature. The table summarizes the main requirements.
| Requirement | When it applies | What employers must do |
|---|---|---|
| Water | Whenever the rule applies (82 F or more) | Provide free, fresh, suitably cool drinking water close to work areas and cool-down areas |
| Cool-down areas | 82 F or more | Shade from sun and radiant heat, ventilate or cool the space, keep it below 82 F unless infeasible; workers may take preventive cool-down rests |
| Measurement and records | When employees may be exposed to 82 F or more | Measure temperature and heat index where employees work; keep records 12 months or until the next measurements, whichever is later |
| Engineering controls | 87 F temperature or heat index; or 82 F with heat-restrictive clothing or high radiant heat | Reduce heat with ventilation, fans, evaporative coolers, air conditioning, insulation or shielding, unless infeasible |
| Administrative controls and PPE | When engineering controls do not get conditions low enough | Schedule changes, cool rest breaks, job rotation, reduced pace, then personal cooling equipment |
| Acclimatization | New employees | Close observation by a supervisor or designee for the first 14 days |
| Emergency response and training | Always | Communication, first aid and transport procedures; training on risk factors, symptoms and reporting |
| Written plan | Always | Written Heat Illness Prevention Plan covering the elements above |
The rule defines a heat wave as any day with a predicted high of at least 80 F that is at least 10 F above the average high of the preceding five days. Restrictive clothing means full-body coverings such as waterproof, chemical or fire-protective garments. Radiant heat includes the sun, hot objects, hot liquids, hot surfaces and fire. That is why ovens, dryers and sun-baked metal walls count.
Cal/OSHA’s indoor heat FAQ lists engineering control examples. They include more natural ventilation when it is cooler outside, cooling fans or air conditioning, local exhaust at points of high heat or moisture, reflective shields, insulating or isolating heat sources, eliminating steam leaks, cooled seats or benches, and evaporative coolers.
Who is covered by the indoor heat rule, and who is exempt?
The rule covers all indoor work areas where the temperature reaches 82 F while employees are present. The exemptions are narrow:
- Telework locations the employer does not control.
- Incidental exposures of less than 15 minutes in any 60-minute period when the temperature is between 82 F and 95 F.
- Emergency operations that protect life or property.
- Certain state and local detention and correctional facilities.
The 15-minute exemption does not apply to vehicles without effective and functioning air conditioning, or to shipping and intermodal containers during loading, unloading and related work. That catches box trucks, trailers at docks and container unloading, all common in Kern logistics. Employers covered by both the indoor and outdoor rules, such as a warehouse with a yard crew, need to address both.
How does the indoor heat rule play out in Kern County?
Summer highs on the San Joaquin Valley floor routinely run well above 82 F. In buildings that rely on ventilation instead of air conditioning, roofs and walls absorb heat through the afternoon, and dock doors open to the yard let it in.
Under those conditions, an uncooled warehouse can cross 82 F early in the day and 87 F by afternoon. The hot spots are usually near the roof deck, at south and west dock walls, inside trailers, and near ovens, dryers or compressors. Once the 87 F line is crossed, the question becomes which engineering controls are feasible in that building. That is a real estate question as much as a safety one.
What building upgrades help warehouses comply?
The rule does not require air conditioning everywhere. It requires feasible controls to reduce heat, and the right mix depends on the building. Common approaches in industrial buildings include:
- Air movement. High-volume, low-speed (HVLS) ceiling fans move air, and exhaust fans pull in outside air when it is cooler than the air inside.
- Evaporative cooling. It works well in dry Valley heat, but it needs water, drainage and maintenance, and it raises humidity, which affects the heat index.
- Spot or zoned HVAC. Air-conditioned packing, kitting or assembly zones work, and so do air-conditioned break rooms that double as cool-down areas.
- Envelope improvements. Roof and wall insulation, reflective or cool roofing, and dock seals or shelters limit hot air at open doors.
- Shielding. Barriers or insulation around ovens, dryers, kilns and other radiant heat sources cut exposure.
Costs vary widely by building.
Each option has utility consequences. HVAC zones and large fan arrays need electrical capacity, and national brokerage research has described power availability as a key driver of industrial property value. Tenants with heavy cooling needs depend on amperage, transformer capacity and utility timelines, and owners need to know what the building can support. See our guides to power for industrial users and industrial building specs. Storage layouts also interact with cooling, so see our explainer on ESFR sprinklers and high-piled storage.
Who pays for heat compliance: landlord or tenant?
The regulation puts the duty on the employer, which is usually the tenant. The lease decides who pays for the building changes. Three clauses do most of the work:
- Compliance with laws. Does the tenant comply with laws that apply because of its particular use, or with all laws?
- Repair and capital replacement. Who pays for new HVAC or roof work, and is the cost amortized?
- Alterations. Does the tenant need consent to add fans, coolers or electrical service, and must it remove them at lease end?
Many California industrial leases, including commonly used association forms, address how capital costs required by new laws are shared. Terms vary widely by form version and negotiation. Tenants often raise heat controls in the letter of intent, ask for cooling or electrical upgrades as part of the tenant improvement allowance, and settle who owns the added equipment. Owners repositioning older buildings may find that partial cooling, insulation and power upgrades widen the tenant pool. A real estate attorney should review the lease language.
What is the status of federal OSHA’s heat rule, and is California changing its rule?
Federal OSHA published a proposed heat injury and illness prevention standard on Aug. 30, 2024. According to Ogletree Deakins, the comment period closed Jan. 14, 2025, a post-hearing comment period ended Oct. 30, 2025, and as of April 2026 the federal regulatory agenda gave no target date for final action. Ogletree also noted that OSHA’s heat National Emphasis Program was set to expire April 8, 2026. OSHA renewed the program on April 10, 2026, EHS Leaders reported. A federal rule would not displace California’s stricter standard.
California is revising its own rules too. In August 2026, Cal/OSHA released a revised discussion draft that would amend both the outdoor (section 3395) and indoor (section 3396) heat standards. According to law firm Seyfarth Shaw, the draft would make the two more consistent in structure and terminology. It would also add acclimatization steps for workers returning after 14 or more days away, and require employers to distribute their heat illness prevention plans at hire, during training and at least once a year. Cal/OSHA set a Sept. 21, 2026 deadline for comments. It is a discussion draft, not formal rulemaking, so today’s section 3396 remains the rule.
Indoor heat compliance checklist for Kern warehouse owners and tenants
- Map hot spots: Walk dock doors, mezzanines, upper racking, trailer interiors, and areas near ovens, dryers or compressors.
- Measure and record: Measure temperature and heat index where people work, and keep the records at least 12 months or until the next measurements.
- Set up cool-down areas: Keep them below 82 F, sized for the number of workers on break at one time.
- Write the plan: Adopt a written Heat Illness Prevention Plan, train workers and supervisors, and plan close observation for new hires during their first 14 days.
- Evaluate controls: Evaluate engineering controls for every area that can reach 87 F, and document why any option is infeasible.
- Size the utilities: Electrical and water capacity set how many HVAC zones, fans or evaporative coolers a building can add.
- Put it in the lease: New leases and renewals can allocate heat-related capital costs, equipment ownership and restoration in writing.
- Track the rules: Cal/OSHA’s revision process and any federal OSHA action are still open. For other workplace rules, see California employment laws in 2026 and the AB 701 warehouse quota law.
Illustrative scenario: a Bakersfield distribution center in July
This scenario is illustrative, not a measured case. A tenant leases an older 150,000-square-foot Bakersfield warehouse with ventilation fans but no air conditioning. In July its measurements show the conditions below, and section 3396 drives a different response in each area.
| Area | Measured condition | What the rule requires | Possible response |
|---|---|---|---|
| Main storage aisles | 84 F temperature, 83 F heat index | Water, cool-down access, plan, training, records | Keep fans running; document measurements |
| Packing line near west dock | 89 F heat index | Engineering controls unless infeasible | Spot cooling or an air-conditioned packing zone; dock seals |
| Trailer unloading | Container interior above 95 F | 15-minute exemption does not apply to containers | Rotation, cooling breaks, portable cooling, early-morning unloading |
| Break room | 78 F | Cool-down area below 82 F | Use as the primary cool-down area; size for shift breaks |
Frequently asked questions
When did the Cal/OSHA indoor heat rule take effect?
The Standards Board approved Title 8, section 3396, on June 20, 2024, and it took effect July 23, 2024. It applies to indoor workplaces across California, including Kern County warehouses, factories, packing sheds and shops. It remains in force while Cal/OSHA works on revisions.
At what temperature does California’s indoor heat rule apply?
It applies when the indoor temperature reaches 82 F with employees present. Employers then owe water, cool-down areas, a written plan, training and measurements. Engineering controls become mandatory at 87 F, or at 82 F where workers wear heat-restrictive clothing or work near high radiant heat such as ovens or furnaces.
Does the indoor heat rule require air conditioning in warehouses?
Not everywhere. Employers must use feasible engineering controls once conditions reach 87 F, and Cal/OSHA lists ventilation, fans, evaporative coolers, insulation, shielding and air conditioning as options. Cool-down areas must stay below 82 F unless that is infeasible, so an air-conditioned break room is a common answer. If controls fall short, administrative steps and personal cooling equipment follow.
Who pays for warehouse cooling upgrades, the landlord or the tenant?
The employer, usually the tenant, is responsible for compliance. The lease decides who funds building changes, mainly through its compliance-with-laws, capital repair and alterations clauses. Many tenants negotiate cooling or electrical upgrades into their improvement allowance, and the letter of intent is the usual place to raise it.
Does the indoor heat rule apply to trucks and shipping containers?
In many cases, yes. The exemption for brief exposures of under 15 minutes per hour does not cover vehicles without working air conditioning or shipping and intermodal containers during loading and unloading. That pulls trailer and container work at Kern distribution centers into the rule’s measurement and control requirements.
What records does the indoor heat rule require?
Employers measure temperature and heat index where employees work when conditions may reach 82 F. They must keep those records for 12 months or until the next measurements, whichever is later. They also need a written Heat Illness Prevention Plan that describes their procedures and controls.
Is there a federal OSHA heat standard?
Not yet. Federal OSHA proposed one on Aug. 30, 2024, and comments closed in 2025. As of April 2026, the federal regulatory agenda showed no target date for a final rule, and Ogletree Deakins described near-term finalization as unlikely. California employers must follow the state’s indoor and outdoor heat rules regardless.
If heat controls, power or cool-down space are shaping your next warehouse decision, Kern CRE can help you compare Kern County buildings and lease terms with those needs in mind. Call Kern CRE at 855-KERN-CRE (855-537-6273) or contact us. Get Kern County CRE news monthly: subscribe to the Kern CRE report.
Sources
- Title 8, Section 3396: Heat Illness Prevention in Indoor Places of Employment, California Department of Industrial Relations, operative July 23, 2024.
- Heat Illness Prevention Guidance and Resources, Cal/OSHA (DIR).
- Indoor Heat Illness Prevention: Frequently Asked Questions, Cal/OSHA (DIR).
- Indoor Heat Illness Prevention Resources and Model Program, Cal/OSHA (DIR).
- OSHA’s Heat Program to Expire While Heat Standard Stalls, Dee Anna D. Hays and Karen F. Tynan, Ogletree Deakins, April 8, 2026.
- OSHA Renews Heat Hazard Emphasis Program, EHS Leaders, April 2026.
- Regional brokerage market reports (Bakersfield industrial, Q2 2026).
- Some Like It Hot! Cal/OSHA Revises Its Heat Illness Proposal, Ilana R. Morady and Patrick Joyce, Seyfarth Shaw, via Mondaq, Aug. 27, 2026.
- Regional brokerage market reports (Feb. 26, 2026).
About this article
Kern CRE prepared this article with help from AI research and writing tools. An editor reviewed the draft, checked its facts against the sources linked above and edited it for accuracy and clarity. It is general information about California workplace safety rules, not legal, tax, investment or financial advice; talk with a qualified professional about your situation.